Table of Contents
Features of the SLC500 analyzer
PLC Versions
All versions
SLC500 - Programming workbench
The Rockwell Software “RSLogix500” is the system software required to develop code SLC500, communicate and load / unload the code in the PLC.
SLC500 - Source file
The files recognized by the Itris Automation Square tools are *.SCL and *.SY6.
The export of these files is made from RSLogix500 programming workbench.
Export Files
Open the project with RSLogix500 programming workbench and :
File→Save As→Type choose export Library Files (*.SLC)
Files generated are :
- SCL file
- SY5 file
- SY6 file
- FIX file
- FIX2 file
Only SCL and SY6 files are required for conversion.
SLC - File
- Content : All application :
- hardware configuration,
- code,
- code comment,…
- last variables values
- How do I get this file? : See Export SCL file
SY6 - File
- Content : variables name and comment
- How do I get this file? : See Export SY6 file
Languages
Ladder
Only this language is available.