====== 110202 ====== Message: " {entity} is not supported by Unity-Pro. Please review the destination file." Example: " RCV_TLG is not supported by Unity-Pro. Please review the destination file." Explanation: ===== CALL_MODEM ===== ^ Function ^ Difficulty ^ Knowledge ^ Time ^ | COM | | GENE_API | | ===== RCV_TLG ===== The RCV_TLG function allows to read data with 'telegram' type from a remote PL7 application. ===== READ_PCM_EXT ===== The READ_PCM_EXT function allows to transfer the data from the archiving zone of the memory card to the memory RAM of the PLC (Words %MW). ===== READ_PCMCIA ===== The READ_PCMCIA function transfer the data from the archiving zone of the memory card to the memory RAM of the PLC. The parameters are different between Unity-Pro and PL7. ^parameters ^ Description ^ parameters PL7 ^ parameters Unity-Pro ^ |**Slot_Number**|slot in PCMCIA card |Inexistant |Int| |**Source_Address**|Storage address (source)|Dword|Dint| |**Words_Number**|Number of words to read|Word|Int| |**Dest_Address**|Destination address|Word|Int| |**Read_State**|Code result|Word|Int| ===== SERVER ===== The SERVER function allows to process the UNI-TE requests immediately from the user program. It depends on PL7 hardware. It is used only to treat the requests coming from Modbus communication. ^parameters ^ Description ^ parameters PL7 ^ parameters Unity-Pro ^ |**Address**|Address of the entity destinataire |Word_Array|array of int| |**rqrp**|request response|Word_Array|Array_of_Int| |**Management_Param**|parameters of management (2 words)|Word_Array|Array_of_Int| ===== SET_PCMCIA ===== Translate this function with the Unity-Pro SET_PCMCIA function and add the slot parameter The parameters are: ^parameters ^ Description ^ parameters PL7 ^ parameters Unity-Pro ^ |**Slot_Number**|slot of the PCMCIA card |inexistant|Int| |**Address**|Address of the archiving area from which initialisation starts|Dword|Dint| |**Words_Number**|Number of words to be initialized|Word|Int| |**Init_Value**|Value of initialization|Word|Int| |**Init_State**|Code giving the result of the execution of the initialization order|Word|Int| ===== WRITE_PCMCIA ===== Translate this function with the Unity-Pro WRITE_PCMCIA function and add the slot parameter The parameters are: ^parameters ^ Description ^ parameters PL7 ^ parameters Unity-Pro ^ |**Slot_Number**|slot of the PCMCIA card |inexistant|Int| |**Address**|Address of the archiving area from which initialisation starts|Dword|Dint| |**Words_Number**|Number of words to be initialized|Word|Int| |**Source_Address**|Starting address of zone (in the PLC) to be copied in the PCMCIA card.|Word|Int| |**Write_State**|Code giving the result of the execution of the initialization order|Word|Int| ===== REGDFB ===== The Regdfb functions in PL7 and Unity-Pro didn't have the same parameters. Warning for Unity-Pro the %SW76 system word is reserved for receiving the result of the registration of the diagnostic DFB but for PL7 it is the %SW160 system word. ^parameters ^ Description ^ parameters PL7 ^ parameters Unity-Pro ^ |**Controlled_Area**|Zone of the machine monitored by the DFB : 0 to 15|Word|Int| |**Error_Class**|Class of the error |Word|Int| |**Status_Length**|Length of the status : 0, 2 or 4 bytes|Word|Int| |**Operator_Ctrl**|Acknowledge operator|Bool|Bool| |**Pin_Number**|Number of the input in error|Inexistant|Int| |**Pin_Value**|Value attended on the input in error|Inexistant|Bool| |**Comment**|Default Error message associated to the DFB instance|String|Inexistant| |**Instname**|Name of the instance in default|Word_array|Inexistant| |**Adrprog**|Program address of the DFB instance in default|Word_array|Inexistant| |**Status**|Status of the DFB|DWord|Dint| |**Error_Id**|Identification of the error.|Word|Int| |**Reg_Status**|Report of the registration of the error|Word|Int| ===== REGIO ===== Inexistant in Unity-Pro and no documentation on the PL7 procedure. ===== ADJUST ===== This function allows to adjust (read and write) of the objects language (one object at a time), by driving internal words of the PLC memory, from a CCX 17 or a MAGELIS. The parameters are: ^parameters ^ Description ^ parameters PL7 ^ |**En**|allow the execution of the ADJUST function|In Bool| |**R_W**|define the type of operation to make|In Bool| |**Type1 **|define the type of object to read or to write|In Word| |**Adr **|contains the address of the object to read or to write|In Word_array| |**Val **|contains the value to write in the object|In Dword| |**Sinc **|allow to set to 1 the value of the bit or to increase of 1 the value of the word or double word|In Bool| |**Rdec **|allow to set to 0 the value of the bit or to decrease of 1 the value of the word or double word |In Bool| |**Vret **|contains the value of the parameter that has been read|Out Dword| |**Gest **|buffer parameter to receive and send the requests(24 words)|Out Word_array| ===== ASK_MSG ===== This function allows to display to the screen of a CCX 17 desk a message with a variable editable by the operator. The parameters are: ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data **|datas to be emitted |In Word_Array| |**Val **|datas received|Out Word_Array| |**Iout **|report |InOut Word_Array| ===== ASK_VALUE ===== This function allows to display, to the screen of a CCX 17 desk, a status message contained in the memory of the operator CCX17 dialog desk. The parameters are: ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Nask**| data to be emitted |In Word| |**Val **|datas received|Out Word_Array| |**Iout **|report |InOut Word_Array| ===== ASSIGN_KEYS ===== This function allows to define the configuration of the associated control keys (bit or not, operating mode of the key, affectation by the CCX 17 ...) and to send it via internal words (%MWi) to be displayed on the screen of a CCX17 desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the address of the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| |**Iout **|report |InOut Word_Array| ===== CONTROL_LEDS ===== This function allows to control the state of the relays or of the lights of the CCX17 desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| |**Iout **|report |InOut Word_Array| ===== DISPLAY_ALRM ===== This function allows to display a alarm message contained in the memory of the operator CCX17 dialog desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**nala**|number of alarm|In Word_Array| |**Iout **|report |InOut Word_Array| ===== DISPLAY_GRP ===== This function allows to display simultaneously a group of messages of status contained in the memory of the operator CCX17 dialog desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**ngrp**|Number of group of messages|In Word_Array| |**Iout **|report |InOut Word_Array| ===== DISPLAY_MSG ===== This function allows to display a message contained in the memory of the operator CCX17 dialog desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**nmsg**|number of message|In Word_Array| |**Iout **|report |InOut Word_Array| ===== GET_MSG ===== This function allows to display to the screen of a CCX 17 desk, a message with a variable editable by the operator. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| |**Iout **|report |InOut Word_Array| ===== GET_VALUE ===== This function allows to display, to the screen of a CCX 17 desk, a status message contained in the memory of the operator CCX17 dialog desk. ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| |**Iout **|report |InOut Word_Array| ===== PANEL_CMD ===== This function allows to send to the dialog operator desk various controls : printing, alarm management.... ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| ===== SEND_ALARM ===== This function allows to send a alarm message to the CCX17 desk ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array| ===== SEND_MSG===== This function allows to send a status message to the CCX17 desk ^parameters ^ Description ^ parameters PL7 ^ |**Adr **|Contain the access path (addressing) to the CCX 17 dialog desk|In Word_Array| |**Data**|datas to be emitted|In Word_Array|